{"product_id":"dometic™-38362-rv-furnace-model-dfla40211-40-000-btu-lp-natural-gas-120v-ac","title":"Dometic™ 38362 RV Furnace – Model DFLA40211 – 40,000 BTU – LP \/ Natural Gas – 120V AC","description":"\u003ch1\u003eDometic™ 38362 RV Furnace – Model DFLA40211 – 40,000 BTU – LP \/ Natural Gas – 120V AC\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eDFL Series | Single Stage | Bottom Discharge | Large Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 38362\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e DFLA40211\u003cbr\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e DFL (Large Series)\u003cbr\u003e\u003cstrong\u003eFuel Type:\u003c\/strong\u003e LP Gas \/ Natural Gas Compatible\u003cbr\u003e\u003cstrong\u003eBTU Output:\u003c\/strong\u003e 40,000 BTU\u003cbr\u003e\u003cstrong\u003eHeating Stage:\u003c\/strong\u003e Single Stage\u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Volt AC\u003cbr\u003e\u003cstrong\u003eDischarge Type:\u003c\/strong\u003e Bottom Discharge\u003cbr\u003e\u003cstrong\u003eAccess Door Required – Part #33058 (Sold Separately)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eWall Thermostat Required (Sold Separately)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDometic™ 38362 (Model DFLA40211)\u003c\/strong\u003e is a powerful \u003cstrong\u003e40,000 BTU single-stage RV furnace\u003c\/strong\u003e designed for large coach applications requiring strong and consistent bottom-discharge heating.\u003c\/p\u003e\n\u003cp\u003ePart of the \u003cstrong\u003eDFL Series\u003c\/strong\u003e, this furnace operates on \u003cstrong\u003e120 Volt AC power\u003c\/strong\u003e and supports LP gas or Natural Gas configurations depending on installation setup.\u003c\/p\u003e\n\u003cp\u003eThis is a \u003cstrong\u003esingle-stage heating system\u003c\/strong\u003e, meaning it operates at full rated BTU output when heating is called for — delivering reliable, straightforward performance for larger fifth wheels, park models, and destination trailers.\u003c\/p\u003e\n\u003cp\u003e⚠ \u003cstrong\u003eImportant:\u003c\/strong\u003e This furnace requires exterior access door \u003cstrong\u003ePart #33058\u003c\/strong\u003e, sold separately.\u003cbr\u003e⚠ A compatible wall thermostat is also required and sold separately.\u003cbr\u003e⚠ Always measure your existing cut-out before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e40,000 BTU high-output performance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSingle-stage heating system\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eLP Gas or Natural Gas compatible\u003c\/li\u003e\n\u003cli\u003e120 Volt AC operation\u003c\/li\u003e\n\u003cli\u003eBottom discharge airflow configuration\u003c\/li\u003e\n\u003cli\u003eLarge-size furnace chassis\u003c\/li\u003e\n\u003cli\u003eDesigned for higher heat demand applications\u003c\/li\u003e\n\u003cli\u003eRequires access door #33058 (sold separately)\u003c\/li\u003e\n\u003cli\u003eRequires wall thermostat (sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 38362\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e DFLA40211\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e DFL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBTU Rating:\u003c\/strong\u003e 40,000 BTU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Stage:\u003c\/strong\u003e Single Stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Type:\u003c\/strong\u003e LP \/ Natural Gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Volt AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge Configuration:\u003c\/strong\u003e Bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 16-1\/2 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 9 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 20 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExterior Door Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Door:\u003c\/strong\u003e 33058\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eInstallation Notes\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eBottom discharge integrates into floor duct systems\u003c\/li\u003e\n\u003cli\u003eExterior access door #33058 is required for proper venting and combustion airflow\u003c\/li\u003e\n\u003cli\u003eConfirm gas type configuration before installation\u003c\/li\u003e\n\u003cli\u003eMeasure existing cut-out dimensions for compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions (FAQ)\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this a two-stage furnace?\u003c\/strong\u003e\u003cbr\u003eA: No. This is a \u003cstrong\u003esingle-stage furnace\u003c\/strong\u003e that operates at full 40,000 BTU output when activated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this include the access door?\u003c\/strong\u003e\u003cbr\u003eA: No. Exterior access door #33058 must be purchased separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this propane or natural gas?\u003c\/strong\u003e\u003cbr\u003eA: It can operate on LP gas or natural gas depending on configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage does it use?\u003c\/strong\u003e\u003cbr\u003eA: 120 Volt AC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does bottom discharge mean?\u003c\/strong\u003e\u003cbr\u003eA: Heated air flows downward into the RV’s floor duct system.\u003c\/p\u003e","brand":"RV Furnace Guys","offers":[{"title":"Default Title","offer_id":47857608261873,"sku":null,"price":2098.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0784\/4941\/0289\/files\/38362.png?v=1772400705","url":"https:\/\/www.rvfurnaceparts.com\/products\/dometic%e2%84%a2-38362-rv-furnace-model-dfla40211-40-000-btu-lp-natural-gas-120v-ac","provider":"RV Furnace Guys","version":"1.0","type":"link"}